Model
|
RR2035RSDES
|
RR2035RPHES
|
RR2035RSDML
|
RR2035RPHML
|
RR2035ASDES
|
RR2035AXHES
|
RR2035ASDML
|
RR2035AXHML
|
Maximum number of drives installable |
3.5", 2.5" SATA or SSD |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
Type of power supply |
500 Watts Redundant power supply |
Yes |
Yes |
Yes |
Yes |
N/A |
N/A |
N/A |
N/A |
500 Watts ATX power supply |
N/A |
N/A |
N/A |
N/A |
Yes |
Yes |
Yes |
Yes |
Connection to System |
Via any eSATA port |
Yes, up to to 5 drives/port |
Yes, up to to 5 drives/port |
N/A |
N/A |
Yes, up to 5 drives/port |
Yes, up to to 5 drives/port |
N/A |
N/A |
Via USB 3.0 / 2.0 port |
Yes (with optional USB 3.0 - eSATA adapter) |
Yes (with optional USB 3.0 - eSATA adapter) |
N/A |
N/A |
Yes (with optional USB 3.0 - eSATA adapter) |
Yes (with optional USB 3.0 - eSATA adapter) |
N/A |
N/A |
Via Multilane SATA port |
N/A |
N/A |
Yes (up to 20 drives) |
Yes (up to 20 drives) |
N/A |
N/A |
Yes (up to 20 drives) |
Yes (up to 20 drives) |
Supported RAID options |
RAID 1, RAID 0 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
RAID 10 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
BIG (SPAN) |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
RAID 5 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Clone Mode |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
(individual drive) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
Yes (when connected to PM compatible controller) |
RAID setup and monitoring software utility support |
available for Windows |
available for Windows |
available for Windows |
available for Windows |
available for Windows |
available for Windows |
available for Windows |
available for Windows |
RAID Setup |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
via software utility or onboard jumpers |
Integrated Port Multiplier |
AD5HPMSXA |
AD5HPMSXA |
AD5HPMSXA |
AD5HPMSXA |
AD5HPMSXA |
AD5HPMSXA |
AD5HPMSXA |
AD5HPMSXA |
RAID Diagnostics |
via software or LED lights |
via software or LED lights |
via software or LED lights |
via software or LED lights |
via software or LED lights |
via software or LED lights |
via software or LED lights |
via software or LED lights |
Drive installation |
mounted onto removable drive tray |
N/A |
20 drives |
N/A |
20 drives |
N/A |
20 drives |
N/A |
20 drives |
Directly insert or removed from drive slot with no special tool |
20 Drives |
N/A |
20 Drives |
N/A |
20 Drives |
N/A |
20 Drives |
N/A |
Hot Swappable Drives |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Supported OS |
OS ndependent |
OS ndependent |
OS Independent |
OS Independent |
OS ndependent |
OS ndependent |
OS Independent |
OS Independent |