Power Rating  1250-3000 VA
Voltage  230 Vac
Frequency  50/60 Hz (auto- sensing)
Configuration  Rack/Tower
Product Series  Powerware
 
    * Conserves valuable rack space with 2U form factor that includes internal batteries
    * Provides more real power (watts) to protect more equipment and leave room for expanding IT systems with a 0.9 power factor
    * Maximizes availability with extended battery runtime options, hot-swappable batteries and optional maintenance bypass
    * Extends battery runtime for critical devices with load segments
    * Offers choice of rackmount or tower installation with two-in-one form factor (4-post rail kit and tower pedestals included)
    * Delivers control and visibility with free power management software featuring an intuitive user interface
General
LEDs 13 status-indicating LEDs
Topology Line interactive
Diagnostics Full system self-test at power up
Transfer Time 14 ms typical
ROO/RPO Rear deck emergency stop connector (for remote on/off and power off)
Rail Kit/Tower Stand Included with all units
Electrical Input
Nominal Voltage 230 Vac
Voltage Range 160294V
(* The high and low thresholds can be user adjusted using the downloadable UPS Configuration tool)
Frequency 50/60 Hz
Frequency Range 4770 Hz for 50 Hz operation
56.570 Hz for 60 Hz operation
Power Draw of UPS (full load) 1250: 5.4A @230V
1750: 7.6A @230V
2500: 10.9A @230V
3000: 13.0A @230V
Electrical Output
Power Factor 0.9
On Utility Voltage Regulation 184265 Vac
On Battery Voltage Regulation -10%, +6% of nominal
Efficiency Normal or line mode: >94%
Frequency Regulation 0.1 Hz
Over Current Protection Electronic current limit
Load Crest Factor 3:1
Load Segments Two individually controlled output receptacles
Battery
Internal Battery Type 1250/2500 VA: 12V/7.2 Ah; sealed, lead-acid; maintenance free
1750/3000 VA: 12V/9 Ah; sealed, lead-acid; maintenance free
EBM Battery Type 12V/9 Ah
Battery Runtime 1250 VA: 5 min w/internal batteries @100% load (0.9 PF)
1750 VA: 3.5 min w/internal batteries @100% load (0.9 PF)
25003000 VA: 3 min w/internal batteries @100% load (0.9 PF)
Battery Replacement Hot-swappable internal batteries
Start-On-Battery Allows start of UPS without utility input
Communications
Serial Port RS-232 (RJ45) ports
USB Port As standard (HID)
Optional Communications Slots ConnectUPS-MS network management card and ModBus
Cables RS-232 and USB 6-foot communications cables included
Power Management Software Powerware Software Suite CD-ROM (bundled with UPS)
Environmental
Safety Markings CE, cTUVus; C-Tick
Safety Conformance IEC/EN 62040-1-1,; UL 1778
EMC Compliance IEC 62040-2, class B
Operating Temperature 0C to +40C
Storage Temperature -15C to +50C
Relative Humidity 2095% non-condensing
Surge Suppression ANSI C62.41 Category A (formerly IEEE 587)
Audible Noise Max 45 dBA

 

Heat Dissipation Table

Eaton 5130 Model Line Mode, BTUs/hr Battery Mode, BTUs/hr
1250 VA 250 1,682
1750 VA 348 2,340
2500 VA 490 2,559
3000 VA 588 3,071
(Battery fully charged)

Model Selection Guide

Catalog Number Rating (VA/Watts) Input connection Output Receptacles Dimensions
H x W x D, mm
Weight
kg
Rack/Tower Models
PW5130i1250-XL2U 1250/1150 IEC C14-10A (8) IEC-C13-10A 86.2 x 441 x 509 24.3
PW5130i1750-XL2U 1750/1600 IEC C14-10A (8) IEC-C13-10A 86.2 x 441 x 509 26.6
PW5130i2500-XL2U 2500/2250 IEC C20-16A (1) IEC-C19 16A, (8) IEC-C13 10A 86.2 x 441 x 634 33.8
PW5130i3000-XL2U 3000/2700 IEC C20-16A (1) IEC-C19 16A, (8) IEC-C13 10A 86.2 x 441 x 634 33.8
PW5130i3000-XL3U 3000/2700 IEC C20-16A (1) IEC-C19 16A, (8) IEC-C13 10A 130.7 x 441 x 484 34.3

 

Battery Backup Times (in minutes)

Load (VA/Watts) Internal
Batteries
1 EBM 2 EBMs 3 EBMs 4 EBMs
PW5130i1250-XL2U
125/115 119 430 741 1052 1363
313/288 32 150 267 384 502
625/575 15 58 100 143 185
938/863 6 42 77 113 148
1250/1150 5 29 54 79 104
PW5130i1750-XL2U
175/160 80 245 410 575 740
438/400 24 96 168 240 312
875/800 9 36 62 89 115
1313/1200 6 24 42 60 79
1750/1600 3 16 28 41 53
PW5130i2500-XL2U
250/225 77 300 410 780 1064
625/563 28 122 207 309 412
1250/1125 11 55 100 150 206
2153/1938 6 31 59 90 120
2500/2250 3 23 42 63 85
PW5130i3000-XL2U / XL3U
300/270 70 242 448 634 820
750/675 24 105 180 255 330
1500/1350 10 44 73 101 130
2250/2025 5 25 47 69 91
3000/2700 3 17 32 47 62

No additional files, specification sheets, guides or documentation found for product.

Warranty: 2-year Manufact.

Full manufacturers warranty details are available at the manufacturers (EATON) web site.

Unless otherwise specified Techbuy is normally your first point of contact for warranty related returns, further information regarding our warranty policies and consumer guarantees is available on our policies and service & support pages.

To apply for return of a product just go to our returns page.

These terms are in addition to and do not affect any terms, conditions, guarantees and warranties implied by law.

Visitor Reviews

[ There are no visitor reviews for this product yet]

Review Product
Click on a thumbnail to view it below

No related products found.

 
L7: 3 | TM: 7 | LM: 12 | TY: 146 | T: 1790
We accept the following with No surcharge on VISA, Mastercard and Paypal!
© Techbuy Pty Ltd 2000 - 2024 All rights reserved.
All prices shown on techbuy.com.au are in $AUD and inclusive of GST. Prices and availability are subject to change without prior notice. Images displayed are accurate to the best of our knowledge and we will not be held responsible for purchases based soley on these images. All brands and names are trademarks of their respective companies. Shipping Australia wide to all metro and regional areas (Sydney, Melbourne, Brisbane, Adelaide, Perth) and Internationally. For more information, please see our usage policies.