SRT2200XLI Features
APC Smart-UPS SRT 2200VA 230V
- Battery
failure notification
Provides
early-warning fault analysis on batteries enabling timely preventive
maintenance
Operating
mode that by-passes unused electrical components in good power conditions to
achieve high operating efficiency without sacrificing protection
Text
and mimic diagrams that display modes of operation, system parameters and
alarms.
Protects
the initial investment in the UPS when migrating from tower to rack-mount
environment.
Smart-UPS On-Line Features & Benefits
Availability
- Intelligent
battery management
Maximizes
battery performance, life, and reliability through intelligent, precision
charging.
Allows
additional run time to be quickly added as needed.
Ensures
clean, uninterrupted power to protected equipment while batteries are being
replaced
- Automatic
internal bypass
Supplies
utility power to the connected loads in the event of a UPS power overload or
fault.
- Automatic
restart of loads after UPS shutdown
Automatically
starts up the connected equipment upon the return of utility power.
- Temperature-compensated
battery charging
Prolongs
battery life by regulating the charge voltage according to battery
temperature.
Protection
Protects
connected loads from surges, spikes, lightning, and other power
disturbances.
Ensures
clean, uninterrupted power to protected equipment when generator power is
used.
- Input
power factor correction
Minimizes
installation costs by enabling the use of smaller generators and cabling.
Ensures
the product has been tested and approved to work safely with the connected
service provider equipment and within the specified environment.
- Frequency
and voltage regulation
Gives
higher application availability by correcting poor frequency and voltage
conditions without using the battery.
- Resettable
circuit breaker
Easy
recovery from overloads; no need to replace a fuse.
Provides
temporary battery power when the utility power is out.
Marketing Features
- Save
time with easy and convenient remote accessibility.
Network
manageable via serial, USB or optional Ethernet. Includes Powerchute Network
Shutdown Software for convenient monitoring and control, safe operating system
shutdown, and innovative energy management capabilities.
- Avoids
costly power problems by keeping your IT equipment and data protected and
available.
Network
grade power conditioning protects from damaging surges and disruptive noise. The
double conversion architecture provides tight voltage regulation, frequency
regulation ,and zero transfer time to battery during power events.
- Low
operating and maintenance costs with proven reliability and intelligent
battery management.
Intelligent
battery management, pioneered by APC, maximizes battery performance and life
through intelligent, precision temperature compensated charging. Automatic self
tests insure battery reliability and warn customers in advance of battery
replacement. Convenient, easy to connect, hot-swappable battery modules provide
battery replacement without powering down.
- Peace
of mind that comes with full equipment compatibility and reliability of a
leader
Provides
pure sine wave output which is recommended by server manufacturers using active
power factor corrected (PFC) power supplies. Safety agency tested and approved
means that you can deploy Smart-UPS with confidence that they meet or exceed the
industrys most rigorous standards.
Serviceability
- User-replaceable
batteries
Increases
availability by allowing a trained user to perform upgrades and replacements of
the batteries reducing Mean Time to Repair (MTTR)
Provides
notification of changing utility power and UPS power conditions
- Disconnected
battery notification
Warns
when a battery is not available to provide backup power.
- Predicitive
failure notification
Provides
early-warning fault analysis ensuring proactive component replacement.
Periodic
battery self-test ensures early detection of a battery that needs to be
replaced.
Protection
Protects
connected loads from surges, spikes, lightning, and other power
disturbances.
Ensures
the product has been tested and approved to work safely with the connected
service provider equipment and within the specified environment.
- Input
power factor correction
Minimizes
installation costs by enabling the use of smaller generators and cabling.
Ensures
clean, uninterrupted power to protected equipment when generator power is
used.
- Frequency
and voltage regulation
Gives
higher application availability by correcting poor frequency and voltage
conditions without using the battery.
- Resettable
circuit breaker
Easy
recovery from overloads; no need to replace a fuse.
Provides
temporary battery power when the utility power is out.
Adaptability
Protects
the initial investment in the UPS when migrating from tower to rack-mount
environment.
- Plug-and-Play
external batteries
Ensures
clean, uninterrupted power to the loads when adding extra runtime to the
UPS.
- Flash
upgradeable firmware
Install
maintenance releases of firmware remotely using FTP.
Serviceability
Periodic
battery self-test ensures early detection of a battery that needs to be
replaced.
Provides
notification of changing utility power and UPS power conditions
- User-replaceable
batteries
Increases
availability by allowing a trained user to perform upgrades and replacements of
the batteries reducing Mean Time to Repair (MTTR)
- Disconnected
battery notification
Warns
when a battery is not available to provide backup power.
- Predicitive
failure notification
Provides
early-warning fault analysis ensuring proactive component replacement.
Adaptability
Protects
the initial investment in the UPS when migrating from tower to rack-mount
environment.
- Flash
upgradeable firmware
Install
maintenance releases of firmware remotely using FTP.
- Plug-and-Play
external batteries
Ensures
clean, uninterrupted power to the loads when adding extra runtime to the
UPS.
Manageability
Provides
remote power management of the UPS over the network.
Quickly
understand unit and power status with visual indicators.
- InfraStruXure
Manager Compatible
Enables
centralized management via the APC InfraStruXure Manager.
Provides
management of the UPS via a serial port.
Customize
UPS capabilities with management cards.
Manageability
Provides
remote power management of the UPS over the network.
- InfraStruXure
Manager Compatible
Enables
centralized management via the APC InfraStruXure Manager.
Customize
UPS capabilities with management cards.
Provides
management of the UPS via a serial port.
Quickly
understand unit and power status with visual indicators.
Marketing Features
- Low
operating and maintenance costs with proven reliability and intelligent
battery management.
Intelligent
battery management, pioneered by APC, maximizes battery performance and life
through intelligent, precision temperature compensated charging. Automatic self
tests insure battery reliability and warn customers in advance of battery
replacement. Convenient, easy to connect, hot-swappable battery modules provide
battery replacement without powering down.
- Peace
of mind that comes with full equipment compatibility and reliability of a
leader
Provides
pure sine wave output which is recommended by server manufacturers using active
power factor corrected (PFC) power supplies. Safety agency tested and approved
means that you can deploy Smart-UPS with confidence that they meet or exceed the
industrys most rigorous standards.
- Avoids
costly power problems by keeping your IT equipment and data protected and
available.
Network
grade power conditioning protects from damaging surges and disruptive noise. The
double conversion architecture provides tight voltage regulation, frequency
regulation ,and zero transfer time to battery during power events.
- Save
time with easy and convenient remote accessibility.
Network
manageable via serial, USB or optional Ethernet. Includes Powerchute Network
Shutdown Software for convenient monitoring and control, safe operating system
shutdown, and innovative energy management capabilities.
Availability
Allows
additional run time to be quickly added as needed.
- Automatic
internal bypass
Supplies
utility power to the connected loads in the event of a UPS power overload or
fault.
- Automatic
restart of loads after UPS shutdown
Automatically
starts up the connected equipment upon the return of utility power.
- Intelligent
battery management
Maximizes
battery performance, life, and reliability through intelligent, precision
charging.
- Temperature-compensated
battery charging
Prolongs
battery life by regulating the charge voltage according to battery
temperature.
Ensures
clean, uninterrupted power to protected equipment while batteries are being
replaced
Specifications
Output
1.98
KWatts / 2.2 kVA
- Max
Configurable Power (Watts)
1.98
KWatts / 2.2 kVA
230V
Configurable
for 220 : 230 or 240 nominal output voltage
- Output
Voltage Distortion
Less
than 2%
- Output
Frequency (sync to mains)
50/60Hz
+/- 3 Hz
220,
240
3
: 1
Double
Conversion Online
Sine
wave
(2)
IEC 320 C19 (Battery Backup)
(8)
IEC 320 C13 (Battery Backup)
Internal
Bypass (Automatic and Manual)
Input
230V
40
- 70 Hz (auto sensing)
IEC-320
C20, Schuko CEE 7 / EU1-16P, British BS1363A
2.44
meters
- Input
voltage range for main operations
160
- 275 V
- Input
voltage adjustable range for mains operation
100
- 275 (half load) V
1
220,
240
Batteries
& Runtime
Maintenance-free
sealed Lead-Acid battery with suspended electrolyte : leakproof
1
3
hour(s)
1
1
- Battery
Volt-Amp-Hour Capacity
367