All stock codes associated to this product
PSUZIPG1X25060V
Zippy Technology G1X2-5060V,1U Redundant Form,60W, Input Type Power
Factor
Overview
Zippy Technology G1X2-5060V,1U Redundant Form,60W, Input Type Power Factor
Correction (PFC), (DxWxH) 190/7.48 (mm/inch) x 106/4.17 (mm/inch) x 39.5/1.56
(mm/inch), Module G1X-1060V, High Effenciency Series Simple Type: Power
Supply.
Features
- Dimensions (DxWxH): 190mm/7.48" x 106mm/4.17" x 39.5mm/1.56"
- Efficiency: 76% (+/-2%) at 115vac/230vac
- Form Factor: 1 Rack Unit Module (1U Module)
- Hold up time: when ac source shutdown dc output must be maintain 16msec in
regulation limit at normal input voltage(ac115v at 80% of full load)
- Input: PFC
- Leakage current: 3.5ma max. At nominal voltage 264vac
- Over power protection: 120~170%
- Over voltage protection: +3.3v-3.6v~4.3v +5v-5.6v~6.5v; +12v-13.2v~15.0v
- Power good signal: on delay 100ms to 550ms,off delay 1ms
- Safety: to meet ul&cul, tuv, ccc
- Short circuit protection: +12v
- Temperature range: operating 0~70, storage –20~80
- Wattage: 60W
Specifications
- Dimensions: 190.00x106.00x39.50 (mm), 7.48x4.17x1.56 (inch)
- Frequency: 47~63hz
- Input current: 2a (rms) for 115 vac /1a (rms) for 230 vac
- Inrush current: 35a max. For 115 vac /70a max. For 230 vac
- Output Voltage +12V: Output Current Min 0.1. Output Current Max 5.
Regulation Load ±5%. Regulation Line ±1%. Output Ripple and Noise Max 120mV.
- Output Voltage +3.3V: Output Current Min 0. Output Current Max 6.
Regulation Load ±5%. Regulation Line ±1%. Output Ripple and Noise Max 50mV.
- Output Voltage +5V: Output Current Min 0. Output Current Max 6.00.
Regulation Load ±5%. Regulation Line ±1%. Output Ripple and Noise Max 50mV.
- Output Voltage +5VSB: Output Current Min 0. Output Current Max 3.
Regulation Load ±5%. Regulation Line ±1%. Output Ripple and Noise Max 50mV.
- Output Voltage -12V: Output Current Min 0. Output Current Max 0.3.
Regulation Load ±10%. Regulation Line ±1%. Output Ripple and Noise Max 120mV.
- Voltage: 90~264vac full range