All stock codes associated to this product
OR1000ERM1U, CP85197, 5175587, CPOR1000ERM1U, 4712856274301
Cyberpower OR1000ERM1U Smart App UPS Systems
Overview
CyberPower OR1000ERM1U Line-Interactive UPS offers Simulated Sine Wave output
power for office system devices including PCs, workstations, networking devices,
and peripherals. Its typically integrated in the back office and server room
environment to ensure a reliable backup power supply during power
failures.
The UPS has a multifunction LCD display which offers real-time information,
including input and output voltage levels, load and battery levels, battery
runtime, overload warning, and a silent mode. With the network ports on the UPS,
it prevents network devices from being subjected to sudden power surges caused
by lightning, thereby avoiding potential system damage. As for battery
maintenance, the UPS allows battery hot-swapping, which enables users to perform
normal battery maintenance without significant interruption.
- Line-interactive UPS Topology
- Simulated Sine Wave Output
- Overload Protection
- Surge and Spike Protection
- Phone/Fax/Modem/DSL/Network Protection
- USB Connectivity Port
- SNMP/HTTP Remote Management Capability (Optional)
- Energy Saving Technology
- Automatic Voltage Regulation (AVR)
- Hot-swappable Batteries
- EMI and RFI Filtration
- LCD Status Display
- PowerPanel Management Software
Specifications
GENERAL |
|
Phase |
Single
Phase |
Form
Factor |
Rackmount |
UPS
Topology |
Line-interactive |
Energy
Saving Technology |
GreenPower
UPS Bypass Technology |
INPUT |
|
Nominal
Input Voltage ( Vac ) |
230 |
Input
Voltage Range ( Vac ) |
165
~ 271 |
Adjustable
Voltage Range ( Vac ) |
253 ~ 271 Vac |
|
189 ~ 207 Vac |
Input
Frequency ( Hz ) |
50
3 |
|
60
3 |
Input
Frequency Detection |
Auto-sensing |
Rated
Input Current ( A ) |
10 |
Input
Connector Type |
IEC
C14 |
Detachable
Power Cord Plug Type |
IEC
C14 x 1 |
Power
Cord Length (ft.) |
6 |
Power
Cord Length (m.) |
1.83 |
OUTPUT |
|
Capacity
(VA) |
1000 |
Capacity
(Watts) |
600 |
On
Battery Waveform |
Simulated
Sine Wave |
On
Battery Voltage(s) ( Vac ) |
230
10% |
On
Battery Frequency ( Hz ) |
50
10% |
|
60
10% |
Power
Factor |
0.6 |
Automatic
Voltage Regulation (AVR) |
Internal
Current Limiting, Circuit Breaker |
Overload
Protection |
|
Outlet(s)
- Total |
6 |
Outlet
Type |
IEC
C13 x 6 |
Outlet(s)
- Battery & Surge Protected |
4 |
Outlet(s)
- Surge-Only Protected |
2 |
Typical
Transfer Time ( ms ) |
4 |
BATTERY |
|
Runtime
at Half Load ( min ) |
14 |
Runtime
at Full Load ( min ) |
3.5 |
Typical
Recharge Time ( Hours ) |
8 |
Start
On Battery |
Yes |
User-replaceable |
Yes |
Hot-swappable |
Yes |
Battery
Type |
Sealed
Lead-acid |
Replacement
Battery Pack |
RBP0025 |
RBP
Quantity ( pcs ) |
1 |
SURGE
PROTECTION & FILTERING |
|
Surge
Suppression ( Joules ) |
810 |
EMI/RFI
Filtration |
Yes |
Phone/Network
Protection RJ11/RJ45 (Combo) |
1-in,
1-out |
MANAGEMENT
& COMMUNICATIONS |
|
LCD
Panel |
Yes |
LCD
Information Display |
Operation
Type, Power Status, Battery Status, Load Status, Other
Information |
LCD
Setting & Control |
Mode
Setting, Alarm Setting, Input & Output |
LED
Indicators |
Power
On |
HID
Compliant USB Port(s) |
1 |
Serial
Port |
Dry
Contact |
Audible
Alarms |
Battery
Mode, Low Battery, Overload, UPS Fault |
Management
Cable ( pcs ) |
Power
Cord x4, USB Cable x1 |
Power
Management Software |
PowerPanel
Business (Recommended) |
SNMP/HTTP
Remote Monitoring |
Yes
- with optional RMCARD205 |
PHYSICAL |
|
Enclosure
Construction |
Metal |
Color |
Silver |
Rackmount
Ears |
Yes |
PHYSICAL
SIZE - UPS MODULE |
|
Dimensions
(WxHxD) (in.) |
17
x 1.7 x 15.3 |
Dimensions
(WxHxD) (mm.) |
433
x 44 x 389 |
Weight
(lbs.) |
30.2 |
Weight
(kg.) |
13.7 |
Installed
Rack Height ( U ) |
1 |
ENVIRONMENTAL |
|
Operating
Temperature (F) |
32
~ 104 |
Operating
Temperature (C) |
0
~ 40 |
Operating
Relative Humidity
(Non-condensing) ( % ) |
0
~ 95 |
Operating
Elevation ( feet/meters ) |
0-9,843
feet (0-3,000 meters) |
Storage
Temperature (F) |
5
~ 113 |
Storage
Temperature (C) |
-15
~ 45 |
Storage
Relative Humidity
(Non-condensing) ( % ) |
0
~ 95 |
Storage
Elevation ( feet/meters ) |
0-49,213
feet (0-15,000 meters) |
Online
Thermal Dissipation ( BTU/hr ) |
24 |
CERTIFICATIONS |
|
Certifications |
CE,
EAC, RCM |
RoHS |
Yes |